Personal tools
You are here: Home OSCAR Users Documents for Users How to Add Allergy Injection Measurement Group

How to Add Allergy Injection Measurement Group

1) go to: Admin/oscarEncounter/Customize oscarMeasurements
2) Add Measurement Type
  - Type: ALL1
  - Type Description: Allergy 1
  - Display Name: Allergy 1
  - Measuring Instruction: Vial 1
  - Validation: numeric value: 0-1
3) click on "Add"
4) repeat Steps 2-3, substituting the "ALL1" with "ALL2", then  "ALL3" (without the quotes)
5) Go to "Add Measuring Instruction"
6) select Type: Allergy 1, then
  - Measuring Instruction: Vial 2
  - Validation: numeric value: 0-1
7) click on "Add"
8) while you're still in the same window, repeat Steps 6-7, substituting "Vial 2" with "Vial 3", then "Vial 4" (we actually had to add in Vial 0 too)
9) Repeat Steps 6-8, substituting "Allergy 1" with "Allergy 2", then "Allergy 3"
10) Go to "Add Measurement Group"
11) I typed in "AI" (without the quotes) into the name field, and left the style sheet field blank, then clicked on Continue
12) select "Allergy 1", "Allergy 2", and "Allergy 3" from the left and clicked on "Add"

Document Actions
Help us support OSCAR!
Listservs

Subscribe to:

OSCAR Users (this is the most active list)

Medical Office Assistants

Developers

Listserv Archives

Membership

OSCAR users- please register with the OSCARcanada Users Society. There is no cost to be a member of the OSCARcanada Users Society and you will receive periodic updates about important OSCAR developments, news and meetings. Members are also be able to vote at the AGM

Contact Us

Oscar Canada Users Society

#425 - 1917 West 4th Avenue

Vancouver  BC  V6J 1M7

OscarCanadaUserSociety@gmail.com